The ETS method requires more than one trigger event in order to fully restore a captured waveform [24].
|
|
|
The ETS method requires more than one trigger event in order to fully restore a captured waveform [1].
|
|
|
This chapter will describe the ETS mode in detail and discusses the limitations as well as the different implementation methods.
|
|
|
ETS enables a digital oscilloscope to capture signals with a much higher effective sample rate than the actual sample rate of the built-in ADCs.
|
|
|
Subsequently, the oscilloscope will then be able to measure and display signals with a higher frequency.
|
... | ... | @@ -25,16 +25,13 @@ Subsequently, the oscilloscope will then be able to measure and display signals |
|
|
The disadvantages of this method is the fact that the measured signal has to be a periodic signal.
|
|
|
This means that the shape and amplitude of the waveform has to repeat itself at a certain point in time.
|
|
|
And these repetitions have to continue until the oscilloscope is able to correctly reconstruct and display the measured waveform.
|
|
|
Signals measured by the real-time sampling method does not have this restriction. However, most signals generated by man-made machines are indeed repetitive waveforms.
|
|
|
Signals measured by the real-time sampling method does not have this restriction. However, most signals generated by man-made machines are indeed repetitive waveforms [2].
|
|
|
|
|
|
[bibliography]
|
|
|
Example Bibliography
|
|
|
--------------------
|
|
|
The bibliography list is a style of AsciiDoc bulleted list.
|
|
|
{empty} +
|
|
|
|
|
|
[bibliography]
|
|
|
- [[[taoup]]] Eric Steven Raymond. 'The Art of Unix
|
|
|
Programming'. Addison-Wesley. ISBN 0-13-142901-9.
|
|
|
- [[[walsh-muellner]]] Norman Walsh & Leonard Muellner.
|
|
|
'DocBook - The Definitive Guide'. O'Reilly & Associates. 1999.
|
|
|
ISBN 1-56592-580-7. |
|
|
\ No newline at end of file |
|
|
Bibliography
|
|
|
[bibliography]
|
|
|
|
|
|
. TEKTRONIX: [_italic_] Real-Time Versus Equivalent-Time Sampling. [_italic_] [Online] http://www.tek.com/document/application-note/real-time-versus-equivalent-time-sampling[tek.com}
|
|
|
. TEKTRONIX: [_italic_] XYZs of Oscilloscopes. [_italic_] Primer, Tektronix, January 2016. |
|
|
\ No newline at end of file |